Orthonotes
Orthonotes
by the.bonestories
v3.0 Fusion
v3.0 Fusion
PubMed Narrative Review Evidence Moderate

Biomechanical properties of artificial bones made by Sawbones: A review.

Medical engineering & physics | 2023 | Zdero R, Brzozowski P, Schemitsch EH

In-App Reader

Open Source

Journal and index pages often block iframe embedding. This reader keeps the evidence details in Orthonotes and leaves the source page one click away.

Source
PubMed
Type
Narrative Review
Evidence
Moderate

Abstract

[Indexed for MEDLINE] 13. Med Biol Eng Comput. 2023 Dec;61(12):3233-3252. doi: 10.1007/s11517-023-02900-4. Epub 2023 Sep 11. Design considerations for patient-specific bone fixation plates: a literature review. Brouwer de Koning SG(#)(1), de Winter N(#)(1), Moosabeiki V(2), Mirzaali MJ(2), Berenschot A(3), Witbreuk MMEH(4), Lagerburg V(5). Author information: (1)Medical Physics, OLVG Hospital, Oosterpark 9, 1091 AC, Amsterdam, The Netherlands. (2)Department of Biomechanical Engineering, Faculty of Mechanical, Maritime, and Materials Engineering, Delft University of Technology, Delft, The Netherlands. (3)Medical Library, Department of Research and Epidemiology, OLVG Hospital, Amsterdam, The Netherlands. (4)Orthopedic Surgery, OLVG Hospital, Amsterdam, The Netherlands. (5)Medical Physics, OLVG Hospital, Oosterpark 9, 1091 AC, Amsterdam, The Netherlands. v.lagerburg@antoniusziekenhuis.nl. (#)Contributed equally In orthopedic surgery, patient-specific bone plates are used for fixation when conventional bone plates do not fit the specific anatomy of a patient. However, plate failure can occur due to a lack of properly established design parameters that support optimal biomechanical properties of the plate.This review provides an overview of design parameters and biomechanical properties of patient-specific bone plates, which can assist in the design of the optimal plate.A literature search was conducted through PubMed and Embase, resulting in the inclusion of 78 studies, comprising clinical studies using patient-specific bone plates for fracture fixation or experimental studies that evaluated biomechanical properties or design parameters of bone plates. Biomechanical properties of the plates, including elastic stiffness, yield strength, tensile strength, and Poisson's ratio are influenced by various factors, such as material properties, geometry, interface distance, fixation mechanism, screw pattern, working length and manufacturing techniques.Although variations within studies challenge direct translation of experimental results into clinical practice, this review serves as a useful reference guide to determine which parameters must be carefully considered during the design and manufacturing process to achieve the desired biomechanical properties of a plate for fixation of a specific type of fracture. © 2023. International Federation for Medical and Biological Engineering. DOI: 10.1007/s11517-023-02900-4

Linked Wiki Topics

This article has not been linked to a wiki topic yet.

Linked Cases

This article has not been linked to a case yet.

Linked Atlases

This article has not been linked to an atlas yet.