The Journal of arthroplasty | 2001 | Stiehl JB, Komistek RD, Dennis DA, Keblish PA
Journal and index pages often block iframe embedding. This reader keeps the evidence details in Orthonotes and leaves the source page one click away.
[Indexed for MEDLINE] 20. Clin Orthop Surg. 2024 Aug;16(4):570-577. doi: 10.4055/cios23356. Epub 2024 Jul 12. Load-Dependent Characteristics of Cruciate-Retaining and Posterior-Stabilized Total Knee Arthroplasty: A Biomechanical Study. Lee JH(1), Schwarzkopf R(2), Fraipont G(3), Bouzarif G(4), McGarry MH(3), Lee TQ(3). Author information: (1)Southern California Permanente Medical Group, Department of Orthopaedics, Fontana Medical Center, Los Angeles, CA, USA. (2)New York University Langone Orthopedic Hospital, New York, NY, USA. (3)Orthopaedic Biomechanics Laboratory, Congress Medical Foundation, Pasadena, CA, USA. (4)Department of Internal Medicine, Highland Hospital, Oakland, CA, USA. BACKGROUND: Increased load bearing across the patellofemoral and tibiofemoral articulations has been associated with total knee arthroplasty (TKA) complications. Therefore, the purpose of this study was to quantify the biomechanical characteristics of the patellofemoral and tibiofemoral joints and simulate varying weight-bearing demands after posterior cruciate ligament-retaining (CR) and posterior-stabilized (PS) TKAs. METHODS: Eight fresh-frozen cadaveric knees (average age, 68.4 years; range, 40-86 years) were tested using a custom knee system with muscle-loading capabilities. The TKA knees were tested with a CR and then a PS TKA implant and were loaded at 6 different flexion angles from 15° to 90° with progressively increasing loads. The independent variables were the implant types (CR and PS TKA), progressively increased loading, and knee flexion angle (KFA). The dependent variables were the patellofemoral and tibiofemoral kinematics and contact characteristics. RESULTS: The results showed that at higher KFAs, the position of the femur translated significantly more posterior in CR implants than in PS implants (36.6 ± 5.2 mm and 32.5 ± 5.7 mm, respectively). The patellofemoral contact force and contact area were significantly greater in PS than in CR implants at higher KFAs and loads (102.4 ± 12.5 N and 88.1 ± 10.9 N, respectively). Lastly, the tibiofemoral contact force was significantly greater in the CR than the PS implant at flexion angles of 45°, 60°, 75°, and 90° KFA, the average at these flexion angles for all loads tested being 246.1 ± 42.1 N and 192.8 ± 54.8 N for CR and PS implants, respectively. CONCLUSIONS: In this biomechanical study, CR TKAs showed less patellofemoral contact force, but more tibiofemoral contact force than PS TKAs. For higher loads across the joint and at increased flexion angles, there was significantly more posterior femur translation in the CR design with a preserved posterior cruciate ligament and therefore significantly less patellofemoral contact area and force than in the PS design. The different effects of loading on implants are an important consideration for physicians as patients with higher load demands should consider the significantly greater patellofemoral contact force and area of the PS over the CR design. Copyright © 2024 by The Korean Orthopaedic Association. DOI: 10.4055/cios23356 PMCID: PMC11262949
This article has not been linked to a wiki topic yet.
This article has not been linked to a case yet.
This article has not been linked to an atlas yet.