Orthonotes
Orthonotes
by the.bonestories
v3.0 Fusion
v3.0 Fusion
PubMed Original Article Evidence Unclassified

Clinical and Biomechanical Characteristics of Posterior-Stabilized Polyethylene Post Fractures in Total Knee Arthroplasty: A Retrieval Analysis.

The Journal of arthroplasty | 2023 | Kahlenberg CA, Baral EC, Shenoy AA, Sculco PK

In-App Reader

Open Source

Journal and index pages often block iframe embedding. This reader keeps the evidence details in Orthonotes and leaves the source page one click away.

Source
PubMed
Type
Original Article
Evidence
Unclassified

Abstract

[Indexed for MEDLINE] 15. J Knee Surg. 2021 Jun;34(7):745-748. doi: 10.1055/s-0039-1700570. Epub 2019 Nov 6. Accuracy of Bone Resection in MAKO Total Knee Robotic-Assisted Surgery. Sires JD(1), Craik JD(2), Wilson CJ(2). Author information: (1)College of Medicine and Public Health, Flinders University, Adelaide, South Australia, Australia. (2)Department of Orthopaedics, Flinders Medical Centre, Adelaide, South Australia, Australia. Accurate component positioning and planning is vital to prevent malalignment of total knee arthroplasty (TKA) as malalignment is associated with an increased rate of polyethylene wear and revision arthroplasty. The MAKO total knee robotic arm-assisted surgery (Stryker, Kalamazoo, MI) uses a preoperative computed tomography scan of the patient's knee and three-dimensional planning to size and orientate implants prior to bone resection. The aim of this study was to determine the accuracy of the MAKO Total Knee system in achieving the preoperative plan for bone resection and final limb coronal alignment. A series of 45 consecutive cases was performed using the MAKO Total Knee system and Triathlon Total Knee implant (Stryker) between April 2018 and May 2019. The difference between what was planned and what was achieved for bone resection and coronal limb alignment was calculated. A total of 37 patients had their data captured using the MAKO system software. Mean difference from the plan for distal femoral cuts was 0.38mm (0.32) deep/proud, anterior femoral cuts 0.44mm (0.27) deep/proud and tibial cuts 0.37mm (0.30) deep/proud. In total, 99 out of 105 (94.29%) of bone resections were within 1mm of the plan. Mean absolute difference in final limb coronal alignment was 0.78° (0.78), with 78.13% being ≤1.00° of the plan, and 100% being ≤3.00° of the plan. The accuracy in achieving preoperatively planned bone resection and final limb coronal alignment using the MAKO Total Knee system is high. Future research is planned to look at whether this is associated with decreased rates of polyethylene wear and revision arthroplasty. Thieme. All rights reserved. DOI: 10.1055/s-0039-1700570

Linked Wiki Topics

This article has not been linked to a wiki topic yet.

Linked Cases

This article has not been linked to a case yet.

Linked Atlases

This article has not been linked to an atlas yet.