Orthonotes
Orthonotes
by the.bonestories
v3.5 Fusion Pro
v3.5 Fusion Pro
PubMed Original Article Evidence Unclassified

Treatment results with light wires studied by panoramic radiography.

American journal of orthodontics | 1982 | Mayoral G

In-App Reader

Open Source

Journal and index pages often block iframe embedding. This reader keeps the evidence details in Orthonotes and leaves the source page one click away.

Source
PubMed
Type
Original Article
Evidence
Unclassified

Abstract

[Indexed for MEDLINE] 17. Biomed Eng Lett. 2019 Aug 10;9(4):435-447. doi: 10.1007/s13534-019-00128-6. eCollection 2019 Nov. Shape memory alloy actuation of non-bonded piezo sensor configuration for bone diagnosis and impedance based analysis. Srivastava S(1), Bhalla S(2), Madan A(2). Author information: (1)1School of Engineering and Technology, Indira Gandhi National Open University, Maidan Garhi, New Delhi, 110068 India. (2)2Department of Civil Engineering, Indian Institute of Technology Delhi, Hauz Khas, New Delhi, 110016 India. In the recent years, there has been a growing interest in research community towards the application of smart materials for bio-medical structural health monitoring. Amongst the smart materials, directly bonded piezo sensors (DBPS), based on the electro-mechanical impedance (EMI) technique, have been successfully employed for the above purpose. The principle behind the EMI technique is that high frequency excitations (typically > 30 kHz) generated by a surface bonded PZT patch are used to detect changes in structural drive point impedance caused by cracks or any other type of damage. Bone healing and damage have been shown to be successfully monitored using the DBPS. However, in most of the diagnostic cases of live human and animal subjects, directly bonding a PZT patch is always an irritant or hazard for a live subject. To circumvent direct bonding, the authors have developed and experimentally demonstrated a non-bonded piezo sensor (NBPS) configuration as a good alternative to DBPS while maintaining the effectiveness of measurement well within discernible limits. This paper presents further improvement in the NBPS configuration aiming at autonomous operation of the gripping mechanism using shape memory alloy (SMA) wires. The experiments are performed on replicas of femur bone in healthy and osteoporosis state. This paper shows the effective use of SMA clamping for bone identification and its damage assessment in comparison to earlier mechanical gripping using jubilee clamps. This paper also covers impedance based identification applied to SMA and clamp based NBPS configurations. In place of raw admittance signatures, effective drive point impedance is utilized for the purpose of bone diagnostics which provides a more realistic assessment of the condition of bone. © Korean Society of Medical and Biological Engineering 2019. DOI: 10.1007/s13534-019-00128-6 PMCID: PMC6859171

Linked Wiki Topics

This article has not been linked to a wiki topic yet.

Linked Cases

This article has not been linked to a case yet.

Linked Atlases

This article has not been linked to an atlas yet.