Accuracy of Bone Resection in MAKO Total Knee Robotic-Assisted Surgery.

The journal of knee surgery | 2021 | Sires JD, Craik JD, Wilson CJ

In-App Reader

Open Source

Journal and index pages often block iframe embedding. This reader keeps the evidence details in Orthonotes and leaves the source page one click away.

Source
PubMed
Type
Original Article
Evidence
Unclassified

Abstract

[Indexed for MEDLINE] Conflict of interest statement: None declared. 16. Bone Joint J. 2021 Nov;103-B(11):1695-1701. doi: 10.1302/0301-620X.103B11.BJJ-2020-2334.R1. What factors drive polyethylene wear in total knee arthroplasty? : results of a large retrieval series. Currier JH(1), Currier BH(1), Abdel MP(2), Berry DJ(2), Titus AJ(3), Van Citters DW(1). Author information: (1)Thayer School of Engineering, Dartmouth College, Hanover, New Hampshire, USA. (2)Department of Orthopedic Surgery, Mayo Clinic, Rochester, Minnesota, USA. (3)University of New Hampshire at Manchester, Manchester, New Hampshire, USA. AIMS: Wear of the polyethylene (PE) tibial insert of total knee arthroplasty (TKA) increases the risk of revision surgery with a significant cost burden on the healthcare system. This study quantifies wear performance of tibial inserts in a large and diverse series of retrieved TKAs to evaluate the effect of factors related to the patient, knee design, and bearing material on tibial insert wear performance. METHODS: An institutional review board-approved retrieval archive was surveyed for modular PE tibial inserts over a range of in vivo duration (mean 58 months (0 to 290)). Five knee designs, totalling 1,585 devices, were studied. Insert wear was estimated from measured thickness change using a previously published method. Linear regression statistical analyses were used to test association of 12 patient and implant design variables with calculated wear rate. RESULTS: Five patient-specific variables and seven implant-specific variables were evaluated for significant association with lower insert wear rate. Six were significant when controlling for other factors: greater patient age, female sex, shorter duration in vivo, polished tray, highly cross-linked PE (HXLPE), and constrained knee design. CONCLUSION: This study confirmed that knee wear rate increased with duration in vivo. Older patients and females had significantly lower wear rates. Polished modular tibial tray surfaces, HXLPE, and constrained TKA designs were device design factors associated with significantly reduced wear rate. Cite this article: Bone Joint J 2021;103-B(11):1695-1701. DOI: 10.1302/0301-620X.103B11.BJJ-2020-2334.R1

Linked Wiki Topics

This article has not been linked to a wiki topic yet.

Linked Cases

This article has not been linked to a case yet.

Linked Atlases

This article has not been linked to an atlas yet.