Distal Radius Volar T Plate Versus Distal Clavicle Pre-Contoured Locking Plate in Neer 2b Distal Clavicle Fractur: A Randomized Controlled Trial
Journal of Orthopedic and Spine Trauma | 2024 | Amir Mehrvar, Reza Zandi, Mohammad Ali Okhovatpour, Shahab Sarlak
Background: The purpose of the current study was to compare the clinical and radiographic outcomes of distal radius volar T plate and pre-contoured locking plate in distal clavicle fracture. Methods: A total of 60 patients with Neer 2b distal clavicle fracture were included in this study and underwent open reduction and internal fixation (ORIF) between March 2019 and November 2...