Back to OrthoWeb
mcq
general
1 verified links
In the context of osteochondritis dissecans, what does a high T2 signal completely surrounding the fragment in...
A high T2 signal completely surrounding the fragment indicates that fluid has tracked underneath the fragment, suggesting that it is unstable and surgical intervention is required.