Orthonotes
Orthonotes
by the.bonestories
v3.0 Fusion
v3.0 Fusion

Evidence Search

Search reputable indexed orthopaedic literature from multiple scholarly sources, classify the evidence, and link papers directly to wiki topics and cases.

Sources: PubMed, Europe PMC, Crossref

Linking results to Wiki: Modular Taper Junctions & Trunnionosis
Reset
Results are classified automatically from source metadata across PubMed, Europe PMC, and Crossref.
PubMed Crossref
PubMed Original Article Evidence Unclassified

Taper Material Loss in Total Hip Replacements: Is It Affected by Joint Friction?

The Journal of bone and joint surgery. American volume | 2022 | McCarty CP, Park SH, Ho NC, Sangiorgio SN

[Indexed for MEDLINE] Conflict of interest statement: Disclosure: The Disclosure of Potential Conflicts of Interest forms are provided with the online version of the article (http://links.lww.com/JBJS/G932). 3. J Orthop Res. 2018 Nov;36(11):2996-3003. doi: 10.1002/jor.24107. Epub 2018 Jul 26. Role of corrosion in taper failure and head disassociation in total hip arthroplasty o...

PubMed Original Article Evidence Unclassified

No radiological and biological sign of trunnionosis with Large Diameter Head Ceramic Bearing Total Hip Arthroplasty after 5 years.

Orthopaedics & traumatology, surgery & research : OTSR | 2021 | Eichler D, Barry J, Lavigne M, Massé V

[Indexed for MEDLINE] 2. J Bone Joint Surg Am. 2022 May 4;104(9):796-804. doi: 10.2106/JBJS.21.00579. Epub 2022 Feb 15. Taper Material Loss in Total Hip Replacements: Is It Affected by Joint Friction? McCarty CP(1), Park SH, Ho NC, Sangiorgio SN, Ebramzadeh E. Author information: (1)The J. Vernon Luck, Sr., M.D. Orthopaedic Research Center, Orthopaedic Institute for Children in...

Crossref Scholarly Work Evidence Unclassified

Electrochemical Testing of Modular Taper Junctions: Effect of Assembly Force and Head Offset

Advances in Electrochemical Techniques for Corrosion Monitoring and Laboratory Corrosion Measurements | 2019 | William Nelson, Justin Grostefon, Thomas Camino, Robert Hastings

Examinations of retrieved orthopedic implants have demonstrated corrosion; however, the extent of corrosion damage can be quite variable. There are a number of factors that may influence this corrosion, including device design and materials, surgical technique, and patient factors such as lifestyle, activity, and comorbidities that affect the local physiological environment aro...

PubMed Original Article Evidence Unclassified

Role of corrosion in taper failure and head disassociation in total hip arthroplasty of a single design.

Journal of orthopaedic research : official publication of the Orthopaedic Research Society | 2018 | Martin AJ, Jenkins DR, Van Citters DW

[Indexed for MEDLINE] 4. Ann R Coll Surg Engl. 2022 May;104(5):e128-e132. doi: 10.1308/rcsann.2021.0187. Epub 2021 Dec 23. Fracture of a triple-polished tapered cemented femoral stem at the Morse taper after metal-on-metal primary total hip arthroplasty. Díaz-Dilernia F(1), Sanchez-Mele H(1), Zanotti G(1), Comba F(1), Piccaluga F(1), Buttaro M(1). Author information: (1)Institu...

Crossref Journal Article Evidence Unclassified

Evaluation and Treatment of Painful Total Hip Arthroplasties With Modular Metal Taper Junctions

Orthopedics | 2012 | R. Michael Meneghini, Nadim J. Hallab, Joshua J. Jacobs

Modern primary total hip arthroplasty femoral components have evolved to include modular necks. Subsequently, the additional taper junction provides another interface as a potential source for mechanically assisted crevice corrosion, which is a complex process involving fretting and crevice corrosion. Furthermore, it is becoming evident that an adverse local tissue reaction may...

Crossref Scholarly Work Evidence Unclassified

Investigation of modular taper material and design factors that affect mechanically assisted crevice corrosion at the femoral head-stem junctions in total hip arthroplasties

Journal unavailable | Sevi Berna Kocagöz, Steven M. Kurtz

Modularity in total hip arthroplasty (THA) designs allows intraoperative flexibility for the surgeon to adapt leg length and femoral offset to the individual anatomy and gives the option to keep a well-fixed femoral stem and revise femoral head and acetabulum, as needed. In early designs, modularity was only used in the femoral head-stem tapers. In the 1980s-1990s, researchers...